Before installation, read the following instructions carefully. Each Liberty pump is individually factory tested to ensure proper

performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service.

Model

Type

HP

Volts

Phase

Full Load

Amps

FNPT

Discharge

Automatic or

Manual*

Drop in

replacement for

LSG202-RE

1 Stage

2

208\230

1

15

1.25”

Automatic

GP200 OR

GR2000

LSGX202-RE

2 Stage

2

208-230

1

15

1.25”

Automatic

LSG202-REX

1 Stage

2

208\230

1

15

1.25”

Automatic

EXTREME OR

D-SERIES

LSGX202-REX

2 Stage

2

208-230

1

15

1.25”

Automatic

Risk of electric shock.

Note: Make sure the electrical specifications of the control selected properly match the electrical specifications of the

pump. Always refer to control panel instructions for proper installation. A separate branch circuit is recommended. It must

be sized in accordance with the National electric code for the current shown on the pump nameplate and literature.

Risk of electric shock. Always disconnect the pump from the power source before handling or making adjustments.

The electrical connections and wiring for a pump installation should only be made by qualified personnel.

This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric

shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.

DO NOT bypass grounding wires or remove ground prong from attachment plugs.

DO NOT use an extension cord.

This pump requires a separate, properly fused and grounded branch circuit. Make sure the power source is properly

sized for the voltage and amperage requirements of the pump, as noted on the nameplate.

The electrical outlet shall be within the length limitations of the pump power cord, and at least 4 feet above floor level

to minimize possible hazards from flood conditions.

The installation must be in accordance with the National Electric Code, Uniform Plumbing Code, International

Plumbing Code, as well as all applicable local codes and ordinances.

Sump and sewage pumps often handle materials which could cause illness or disease. Wear adequate protective

clothing when working on a used pump or piping.

Never enter a pump basin after it has been used. Sewage and effluent can emit several gases which are poisonous.

Keep clear of suction and discharge openings. To prevent injury, never insert fingers into pump while it is plugged in.

DO NOT use this product for flammable or corrosive liquid.

DO NOT use this product in applications where human contact with the pumped fluid is common (such as swimming

pools, fountains, etc.)

NEVER dispose of materials such as paint thinner or other chemicals down drains, as they can chemically attack and

damage pump components, potentially causing product malfunction or failure.

DO NOT use pumps in water over 140

F (60

C).

DO review applicable codes concerning maximum allowable temperature of water discharged into drain systems.

DO NOT use pumps in mud, sand, cement, oil or chemicals.

DO NOT modify the pump in any way.

DO NOT lift or carry pump by power cord.

DO NOT remove any tags from pump or cords.

If pump is installed during construction before power is available, it must be protected from the environment to prevent

water from entering through the cord plug end, etc.