OPERATION

After the electrical and mechanical installations have been performed, the pump is ready for operation. No operational

procedures are required except to apply rated power to the pump. There are no specific shutdown procedures beyond

disconnecting the power supply.

NOTE: The alarm float if activated will also act as a redundant “ON” float – activating the pump.

ALWAYS ENSURE THAT THE PUMP IS FREE OF WIRES OR OTHER OBSTRUCTIONS THAT MAY CAUSE

HARM OR INJURY.

4-2

PERIODIC MAINTENANCE & LUBRICATION

Liberty pumps are designed for long lasting, efficient and reliable service with a minimum of preventive maintenance checks.

These checks are few but will add years of satisfactory service to the life of the pump. Maintenance checks should be

performed at the intervals stated. Severe operating environments will require more frequent checks.

4-3

LUBRICATION

Ball Bearings: None required

Mechanical Seal: Lubricated by the motor oil

Seal Oil: 32W HIGH Detergent Oil Qty: .7 Gal

NEVER LIFT THE PUMP BY PULLING ON THE POWER CORD. USE THE LIFTING “ROPE” ONLY.

4.

Operation