- 6 -

Discharge elbow

Discharge flange

Rotating cover
cam-locks

3-5 INSTALLING THE RE/REX CORE

1. Apply gasket tape to the under or bottom side of the cover at

the perimeter.

2. Adjust the discharge elbow’s height by sliding it up or down in

the discharge flange - matching that of the unit which was

removed. DO NOT fully tighten the three bolts on the discharge

flange yet. The height of the discharge elbow might need to be

slightly adjusted after the unit is assembled into the pit.

3. Located on the cover are three rotating cam-locks which are

used to secure the unit. The cam-lock must be orientated such

that the pointer aligns with the “OPEN” mark before lowering the

unit into the pit.

4. Float switches must be positioned so that they will be free of

any objects in the tank or tank walls. If adjustments are made to

either one, make sure that floats will activate properly.

Specifically, confirm that the alarm float activates before hitting

top cover.

5. Although the Liberty Pumps RE/REX models come equipped with 6-pin connectors that mate perfectly with existing

control hardware, the following table may be used for troubleshooting, repair, or custom installation purposes.

6. Lubricate the triple O-ring seal on the discharge elbow to ease installation of elbow into

receiver. With what? Is grease packet included?

7. Using the lifting rope, lower the grinder assembly into the basin. Align the cover tabs to the

mating tank slots, and discharge elbow to the receiver/ball valve. The unit should come to

rest squarely on the tank flange.

8. The three cam-locks for the cover should now be secured by rotating the

3/8” hex bolts (9/16 SOCKET) clockwise to the “CLOSED” position. The

cam-locks will wedge under the tank flange securing the cover.

9. Press downward on the discharge elbow such that it seats fully in the ball

valve’s receiver. Tighten the three 3/8 bolts (9/16 SOCKET) on the discharge

flange. This will compress the rubber ring and seal the unit.

10. Open the valve so that the handle/ latch encompasses the discharge elbow. If

problems exist with opening the valve, adjustments can be made to the height of the

discharge elbow by loosening the three screws on the discharge flange and raising

or lowering the height as needed. Be sure to retighten the screws after adjustment.

11. The control box is designed to be mounted higher in the pit’s access chamber and

above a potential flood level should a power outage occur. 8 feet of cable is

provided to the control box to accommodate various pit heights. Mount the control

box as high as possible to the existing vent pipe using the supplied brackets and hose clamps. The brackets must first be

screwed onto the control panel, then install the hose clamps through the slotted openings on the bracket.

12. The 6-pin electrical connector (either round or square) will mate up with the existing E/one® plug in the pit. No splicing is

required. Simply connect the plugs together and ensure they are fully engaged. Note: The manual over-ride switch will

remain operational in the original equipment E/one® panel.

13. An auxiliary or second nameplate is provided and should be fastened to the existing control panel to properly identify the

new pump.

PIN

Function

GP200/GP2000

(square connector body)

Extreme D-Series

(round connector body)

Liberty

RE/REX

1

Manual Run

Red

Brown

Red

2

L1

Black

Red

Black

3

L2

White

Black

Yellow

4

Ground

Green

Green/Yellow

Brown

5

Alarm Feed

Orange

Yellow

Orange

6

Alarm Return

Blue

Blue

Blue