Example: Shared office

An overview of partition characteristics can be found in chapter 15.1 of these
instructions.

The following types can be assigned to one or more partitions: Normal Alarm, Entry
Route, Final Exit, Key Sw Latched, Key Box, Exit Norm. Alm.

If you plan to use internal active partitions, you must ensure that the
internally activated options are identical for all zones used by more than
one partition.
The wireless centre does not allow allocation of the following zone types
to more than one partition: 24 Hour, Fire, PA, Technical Alarm, Key Sw
Moment, Perimeter Warn.

13.10 Selecting zone characteristics

Select the Attributes menu item.

Further properties can be allocated to the zone here.

Property

Meaning

Chime

When the alarm centre is deactivated and this zone is
triggered, the centre emits an acoustic signal.

Soak Test

If a detector tends to trigger false alarms, activate the
detector test (soak test). This setting is automatically
reset after 14 days. During this time, the detector
triggers no alarms on the alarm centre. All triggering
behaviour is noted in the memory (logbook).

Activity Mon.

The detector function is inverted. This is only to be
used in connection with the Social Care function.
An
alarm is triggered on the alarm centre if the detector
reports no alarms within a specific period.

Part Set

This zone is monitored if the partition of this zone or all
partitions are internally activated.

Force Set

If a zone is assigned this property, then this zone is hid
automatically if it was open during activation.

Dis. Sabotage

Installer Menu

Æ Detectors Æ Edit Zones Æ Attributes Æ

Dis. Sabotage Yes /No

xFactory setting: No

xIf “Yes” is selected, sabotage monitoring on the

FTS 96 E wireless window protection system is
switched off when the alarm system is
deactivated.

o“W” is shown in the “Attributes” line in the

display.

Lock

This attribute can only be assigned to a zone of the
"Normal Alarm" type. The partition
can only be set or part set when this zone is closed.
Opening this zone
does not trigger an alarm.