Material safety data sheet – Alpha Technologies Spill Control Barrier System User Manual

Page 18

Advertising
background image

Alpha Industrial Power

Spill Control Barrier System

Revision Date: March 18, 2008

MSDS No. AAG (A)

Installation Manual

Page 17 of 25

MATERIAL SAFETY DATA SHEET

1. MATERIAL IDENTIFICATION

Product Name:

ADHESIVE GEL (RESIN), PART-A

Chemical Family:

Epoxy Resin Mixture

Company Name:

Eastern Resins Corp.

1174 River Street Woonsocket, RI
02895, USA

BUSINESS PHONE:
EMERGENCY PHONE:

(401) 769-6700
(800) 255-3924

2.

COMPOSITION

Exposure Limits

ACGIH

OSHA

Chemical Name

Wt %

TLV-TWA

PEL

Epoxy resin Mixture

>70

N/E

N/E

Titanium Dioxide *

<10

10 mg/m3

15 mg/m3

Carbon black*

<1

3.5 mg/m3

3.5 mg/m3

Fumed silica*

<10

20 mppcf

20mppcf

Specific ingredients are considered a Trade Secret

Abbreviations: N/E - NOT ESTABLISHED

* - Materials are in Non-Airborne form

3. HEALTH HAZARDS

Primary Routes of Exposure:

Eyes: Yes

S kin : Y es

Inhalation:

Yes

Eye Contact: May cause irritation and swelling.
Skin Contact: May cause irritation and sensitization. Symptoms can be immediate or delayed several hours. Inhalation: May cause irritation
and temporary or permanent sensitization.
Ingestion: May cause irritation.
Other: Preexisting skin sensitization may be aggravated by exposure to this product.

4. FIRST AID MEASURES

Eyes: Flush eyes thoroughly with water for at least 15 minutes while holding eyelids open. Seek medical attention.
Skin: Remove contaminated clothing. Wipe excess from skin and wash the affected area thoroughly with soap and water. Wash contaminated clothing thoroughly
before reuse.
Inhalation: Remove to fresh air, and provide oxygen or artificial respiration if needed. Obtain medical attention; symptoms can be delayed up to several hours.
Ingestion: DO NOT induce vomiting. Give 1-2 cups of water or milk unless the person is drowsy, convulsing, or unconscious. Get medical attention.

5. FIRE FIGHTING MEASURES

Flammable Properties: Flash Point:

>300

o

F (PMCC)

Explosive Limits:

Not applicable

Auto-Ignition Temperature:

Not applicable

Hazardous Decomposition Products:

Carbon monoxide, carbon dioxide, aldehydes, and other organic substances.

EXTINGUISHING MEDIA AND FIRE FIGHTING INSTRUCTIONS: When sufficiently large quantities are present, firefighters should be equipped with
full bunker gear, including a positive pressure, NIOSH approved, self-contained breathing apparatus. Extreme heat or water contamination may cause closed
containers to explode.
Extinguishing Media: Use carbon dioxide, dry chemical or appropriate foam

6. ACCIDENTAL RELEASE MEASURES

Ventilate the spill area and evacuate if necessary. Remove all ignition sources. Dike and contain large spills. Clean-up personnel should use adequate protective
equipment.

7. HANDLING AND STORAGE

Store in a cool; dry place, in closed containers at room temperature. Avoid contact with incompatible materials. Wear protective eyewear, chemical-resistant gloves, and
other protective clothing as appropriate.