Material safety data sheet – Alpha Technologies Spill Control Barrier System User Manual

Page 24

Advertising
background image

Alpha Industrial Power

Spill Control Barrier System

Revision Date: March 18, 2008

MSDS No. ANFC (B)

Installation Manual

Page 22 of 25

MATERIAL SAFETY DATA SHEET

1. MATERIAL IDENTIFICATION

ProductName:

NOVOLAC FLOOR COATING (HARDENER), PART-B

ChemicalFamily:

AMINE MIXTURE

Company Name:

Eastern Resins Corp.

1174RiverStreet

BUSINESS PHONE:

(401) 769-6700

Woonsocket, RI 02895, USA

EMERGENCY PHONE: (800) 255-3924

2. COMPOSITION

Exposure Limits
ACGIH

OSHA

ChemicalName

Wt%

TLV-TWA

PE L

Cycloaliphatic amine

50-70

N/E

N/E

Aliphaticamine

30-50

N/E

N/E

Specific ingredients are considered a Trade Secret

Abbreviations: N/E - NOT ESTABLISHED

* - Materials are in Non-Airborne form

3. HEALTH HAZARDS

PrimaryRoutesofExposure:

Eyes: Yes

Skin: Yes

Inhalation:

Yes

Eye Contact: Cause severe irritation and may cause burn.
Skin Contact: Cause irritation and sensitization. Symptomscan be immediate or delayed several hours.
Inhalation: Can cause respiratory tract irritation.
Ingestion: Can cause nausea, headache, and gastrointestinal irritation.
Other: Preexisting skin sensitization may be aggravated by exposure to this product.

4. FIRST AID MEASURES

Eyes: Flush eyes thoroughly with water for at least 15 minutes while holding eyelids open. Seek medical attention.
Skin: Remove contaminated clothing. Wipe excess from skin and wash the affected area thoroughly with soap and water. Wash
contaminated clothing thoroughly before reuse.
Inhalation: Remove to fresh air, and provide oxygen or artificial respiration if needed. Obtain medical attention; symptoms can be
delayed up to several hours.
Ingestion: DO NOT induce vomiting. Give 1-2 cups of water or milk unless the person is drowsy, convulsing, or unconscious. Get
medical attention.

5. FIRE FIGHTING MEASURES

Flammable Properties: Flash Point:

>200

o

F (PMCC)

ExplosiveLimits:

Notapplicable

Auto-IgnitionTemperature:

Not applicable

Hazardous Decomposition Products:

oxides of nitrogen, Carbon monoxide, carbon dioxide and other organic materials.

EXTINGUISHING MEDIA AND FIRE FIGHTING INSTRUCTIONS: When sufficiently large quantities are present,
firefighters should be equipped with full bunker gear, including a positive pressure, NIOSH approved, self-contained breathing
apparatus. Extreme heat or water contamination may cause closed containers to explode.
Extinguishing Media: Use carbon dioxide, dry chemical or appropriate foam.

6. ACCIDENTAL RELEASE MEASURES

Ventilate the spill area and evacuate if necessary. Remove all ignition sources. Dike and contain large spills. Flush area with water
spray. Clean-up personnel should use adequate protective equipment.