Atm and wan interface specifications – Atec Agilent-J2300E User Manual

Page 74

Advertising
background image

74

E3 (34.368 Mb/s) J3759B

General

This interface comprises a plug-in module (J3759B) suitable for plugging into

the J2300C/D/E Advisor mainframe and the J2900A High Speed undercradle.

The J3759B supports both ATM and frame-based technologies such as Frame

Relay (CIR & SLA), HDLC, PPP in addition to BERT. This module can also be

configured for use as a DS3 (44.736 Mb/s) interface; see below for details.

Common to Inputs and Outputs:

Connectors: 75 Ohm BNC female

Electrical: ITU-T G.703

Line Code: HDB3

Framing:

Frame Relay: ITU-T G.751

ATM Direct: ITU-T G.832

ATM PLCP: ITU-T G.751

Cell Mapping:

Direct (normal mode, ITU-T G.804)

PLCP (obsolete mode, ETSI 300 214)

Cell Scrambling:

Conforms to ITU-T I.432.1 (x

43

+ 1) and may be turned on or off

Inputs:

Two ports

Levels:

Auto gain control for high, low and monitor jack; all unbalanced 1.2Vpeak

to 26mVpeak, 34 dB dynamic range

Received pulse amplitude measurement (mVpeak)

Monitor modes:

Terminated/Repeater (75 Ohm unbalanced)

Bridged (high impedance)

Physical Layer Alarms and Statistics:

Loss of Signal (LOS)

Loss of Frame (LOF)

Line code violations

Alarm Indication Signal (AIS)

Remote Defect Indication (RDI), formerly known as FERF

Remote Error Indication (REI), formerly known as FEBE

Bit Interleave Parity (BIP-8)

Payload type mismatch

Loss of Cell Delineation (LCD)

ATM Statistics:

Auto-discovery of up to 1024 VCs and collection of statistics on each

Average utilization in percent

Instantaneous utilization in percent

Maximum utilization in percent

Total cells received

Idle/unassigned cells received

Busy (assigned) cells received

Header (“HEC”) errors

Frame Relay Statistics:

Average utilization in percent

Instantaneous utilization in percent

Maximum utilization in percent

Minimum utilization in percent

Total frames

Total octets

ATM and WAN Interface
Specifications

(continued)

Advertising