Atec Flexim-G601 User Manual

Page 17

Advertising
background image

TSFLUXUS_G601V1-5-1US_Lus, 2014-02-25

17

Technical Specification

FLUXUS® G601

Shear Wave Transducers

technical type

GDM1NZ7

GDP1NZ7

GDQ1NZ7

order code

GSM-NNNNL

GSP-NNNNL

GSQ-NNNNL

transducer frequency

MHz 1

2

4

medium pressure

1

min. extended

psi

metal pipe: 290

metal pipe: 290

metal pipe: 290

min.

psi

metal pipe: 435
plastic pipe: 15

metal pipe: 435
plastic pipe: 15

metal pipe: 435
plastic pipe: 15

inner pipe diameter d

2

min. extended

in

1.2

0.59

0.24

min. recommended

in

1.6

0.79

0.39

max. recommended

in

3.1

1.6

0.79

max. extended

in

4.7

2.4

1.2

pipe wall thickness
min.

in

0.1

0.06

0.04

max.

in

-

-

-

material
housing

stainless steel 304

stainless steel 304

stainless steel 304

contact surface

PEEK

PEEK

PEEK

degree of protection

NEMA 6

NEMA 6

NEMA 6

transducer cable
type

1699

1699

1699

length

ft

13

13

9

dimensions
length l

in

2.36

2.36

1.67

width b

in

1.18

1.18

0.71

height h

in

1.32

1.32

0.85

dimensional drawing

ambient temperature
min.

°F

-40

-40

-40

max.

°F

+266

+266

+266

temperature
compensation

x

x

x

remark

on request

1

depending on application, typical absolute value for natural gas, nitrogen, compressed air

2

shear wave transducer:
typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on request
pipe diameter min. recommended/max. recommended/max. extended: in diagonal arrangement and for a
flow velocity of 49 ft/s

h

b

l

h

b

l

h

b

l

Advertising