Atec Flexim-G601 User Manual

Page 20

Advertising
background image

20

TSFLUXUS_G601V1-5-1US_Lus, 2014-02-25

FLUXUS® G601

Technical Specification

Lamb Wave Transducers

technical type

GRM1NC3

GRP1NC3

GRQ1NC3

order code

GLM-NNNNL

GLP-NNNNL

GLQ-NNNNL

transducer frequency

MHz 1

2

4

medium pressure

1

min. extended

psi

-

-

-

min.

psi

metal pipe:
145 (d > 2.4 in)
73 (d < 2.4 in)
plastic pipe: 15

metal pipe:
145 (d > 1.4 in)
73 (d < 1.4 in)
plastic pipe: 15

metal pipe:
145 (d > 0.59 in)
73 (d < 0.59 in)
plastic pipe: 15

inner pipe diameter d

2

min. extended

in

1.2

0.59

0.28

min. recommended

in

1.6

0.79

0.39

max. recommended

in

3.5

2

0.87

max. extended

in

5.9

2.8

1.4

pipe wall thickness
min.

in

0.08

0.04

0.02

max.

in

0.2

0.12

0.04

material
housing

PPSU with stainless steel
cap 304

PPSU with stainless steel
cap 304

PPSU with stainless steel
cap 304

contact surface

PPSU

PPSU

PPSU

degree of protection

NEMA 4

NEMA 4

NEMA 4

transducer cable
type

1699

1699

1699

length

ft

13

13

9

dimensions
length l

in

2.91

2.91

1.65

width b

in

1.26

1.26

0.87

height h

in

1.59

1.59

1

dimensional drawing

ambient temperature
min.

°F

-40

-40

-40

max.

°F

+338

+338

+338

temperature
compensation

x

x

x

remark

on request

1

depending on application, typical absolute value for natural gas, nitrogen, compressed air

2

Lamb wave transducer:
typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on request
pipe diameter min. recommended/max. recommended: in reflect arrangement and for a flow velocity of 49 ft/s
pipe diameter max. extended: in diagonal arrangement and for a flow velocity of 82 ft/s

l

h

b

l

h

b

l

h

b

Advertising