B&K Precision 2658A - Manual User Manual

Page 77

Advertising
background image

71

37)

Setting marker mode

Command : MKR* * * * *

( * * * * *: NORM / DELTA)

Example: MKRDELTA

Query: MKR?

38)

Setting marker position by frequency

The position of active marker is set by frequency.

Command : NORMMKR* * * * * *

( * * * * * * *: Refer to “25.6 Input of Frequency”)

Query: NORMMKR?

39)

Setting marker position by number of points on horizontal axis

The position of active marker is set by number of points on horizontal axis.

Command : MKRPOSI* * *

( * * *: 0 to 500 ; 0 = far left, 500 = far right)

Example: MKRPOSI40

40)

Setting

peak search mode

Command : PEAK* * * *

( * * * * : NORM / ZONE)

Example: PEAKZONE

Query: PEAK?

41)

Request peak search

Command : PKSEARCH* *

( * *: 01 / 02 / 03 / 04 / 05 / 06

/ 07 / 08 / 09 / 10 / 11)

Example: PKSEARCH09

42)

Setting zone center frequency for peak search

Command : PKCNTR* * * * * * *

( * * * * * * *: Refer to “25.6 Input of Frequency”)

Example: PKCNTR1.345G

Query: PKCNTR?

43)

Setting zone width for peak search

Command : PKWIDTH* * * * * * *

( * * * * * * *: Refer to “25.6 Input of Frequency”)

Example: PKWIDTH256M

Query: PKWIDTH?

Command

Marker mode

NORM

Normal marker

DELTA

Delta marker

Command

Destination of marker

01

The maximum peak on the screen

02

The 2nd peak on the screen

· · ·

· · ·

11

The 11th peak on the screen

Command

Peak search mode

NORM

Normal peak search

ZONE

Zone peak search