DETAILED SPECIFICATIONS - VDC Model No. 24041-AA (con’t.)

Charging Output Control Characteristics

Charging Flow : Battery condition detect>Soft Start Charge>Bulk Charge>Absorption

Charge>Sulphate Check>Float Charge

Soft Start Charging Activity conditions: Battery Voltage is over 6 Vdc and less than 21Vdc

(the charger will start at 1A mode & Gel mode automatically)

Soft Start Charging output current control: (1A / 2A / 4A mode) 1 / 2 / 4 ±0.25 Adc

Soft Start Charging Time Limited: (Stop charge If battery cannot be charged over 10.5V after

6 hrs, Error LED flash indicated) 6 ±0.25 Hours

Bulk Charging Activity conditions: Battery Voltage is over 21Vdc

(the charger will start at

1A mode & Gel mode automatically)

Bulk Charging Current control at 1A mode: (Selected by pressing Charge Rate Button)

1 +0.17 / -0 Adc

Bulk Charging Current control at 2A mode: (Selected by pressing Charge Rate Button)

2 +0.20 / -0 Adc

Bulk Charging Current control at 4A mode: (Selected by pressing Charge Rate Button)

4 +0.22 / -0 Adc

Max. rated output voltage and current: 26.0V at 4Adc 27.2V at .25Adc

Bulk Charging Time Limited: (Stops charge If battery cannot be charged reach 28.2/28.8/28.2V

after 20 hrs, error LED flash indicated) 20 ±1 Hours