Always, Positive ground installations – BatteryMINDer 12248-AA-S1 User Manual

Page 17

Advertising
background image

Rev. F-103007

P/N VDC12248AA-S1-MNL

BatteryMINDer

®

Model 12248-AA-S1

Page 17

Correct polarity and a good connection will be
your reward. Attach the

BCA

to the proper bat-

tery posts, clamps or screw terminals, depending
on type of battery.

ALWAYS

connect the negative

(

BLACK

) clip to a metal grounding point (Negative

ground installations such as most modern cars,
trucks, boats, RVs, etc.) as far away from battery
as possible for maximum safety. Never connect to
any type of fuel line.

Note: Older vehicles or other devices may be

Positive ground installations

requiring differ-

ent connection recommendations. If unfamiliar or
unsure which battery type of grounding system
you have, check with our Tech Support personnel
before proceeding further.

Note

:

Temperature Compensation Sensor

Assembly (Part# ABS-248).

See pages 21 - 24

for full detailed instructions.

3. Press 8A Button twice (2x) until LED lit.
4. Press “Until Aviation Lit” button until LED lights.
5. Plug the unit’s Power cord into a standard
– grounded 120 Vac electrical outlet. The Battery
Connected LED Indicator will light

GREEN

. If it

does not light

GREEN

check the outlet to be

sure it is functioning. In addition, be sure if outlet
is controlled by a switch, no one will accidentally
shut off the power to the outlet. Check for cor-
rect polarity = (no ERROR

RED

LED Indicator). If

ERROR Indicator is lit, reverse the charger’s out-
put connections to the battery.

Advertising