BatteryMINDer 12248-AA-S1 User Manual

Page 30

Advertising
background image

Rev. F-103007

P/N VDC12248AA-S1-MNL

BatteryMINDer

®

Model 12248-AA-S1

Page 30

DETAILED SPECIFICATIONS - VDC Model No. 12248-AA-S1 (con’t.)

Charging Output Control Characteristics

Charging Flow : Battery condition detect>Soft Start Charge>Bulk Charge>Absorption

Charge>Sulfate Check>Float Charge

Soft Start Charging Activity conditions: Battery Voltage is over 3 Vdc and less than 10.5Vdc

Soft Start Charging output current control: (8A mode) 4 ±0.25 Adc

Soft Start Charging Time Limited: (Stop charge If battery cannot be charged over 10.5V after

6 hrs, Error LED flash indicated) 6 ±0.25 Hours

Bulk Charging Activity conditions: Battery Voltage is over 10.5Vdc

Bulk Charging Current control at 8A mode: (Selected by pressing “Until 8A Lit” Button)

Max. rated output voltage and current: 13.0V at 8Adc 13.6V at 6.50Adc

Bulk Charging Time Limited: (Stops charge If battery cannot be charged reach 14.1

after 20 hrs, error LED flash indicated) 20 ±1 Hours

Advertising