iD4

120 V ~ 50/60 Hz 22,6 A 1220 W

1900 W / 4 Ohm



   

  

  

iD4

220 V ~ 50/60 Hz 11,3 A 1220 W

1900 W / 4 Ohm



   

  

  

iD4

230 V ~ 50/60 Hz 11,3 A 1220 W

1900 W / 4 Ohm

3 INST

ALLA

TION

3. Installation

3.1 Mains Supply

When mounting or connecting the amp always disconnect it from mains.
Only connect the iD4 amplifier to an appropriate AC circuit and outlet,
according to the requirements indicated in the second line on the rating
plate.

Exemplary rating plates for the three available amplifier variants.

Power supply data of all available variants:

Operating condition

Mains

current

(4 Ω / 2 Ω)

Power

consumption

(4 Ω / 2 Ω)

Output

power

iD4

Amplifier standby (power off)

< 0,5 A

8 W

0 W

Idle (amplifier powered on)

1,3 A

70 W

0 W

250 W per channel

8,5 / 10 A

1 220 / 1 500 W 500 W

Mains current draw and power consumption @ 230 V, 50 Hz

Measured with pink noise with crest factor of 12 dB to represent typical music signal.

For 120 V mains operation, the current values can be multiplied by 2.

3.2 On / Off Switch

The On / Off Switch is a rocker-type switch. It is located on the right side
of the front panel. To turn the amplifier on, press on the upper part of the
switch. During power up the Clip- and Signal-LEDs from both channels
will light up in red for a few seconds. To turn the amplifier off, press on the
lower part of the switch.

Amplifier is switched on

Amplifier is switched off

l

NOTE

This switch does NOT disconnect the amplifier from mains. Discon-
necting the amplifier from the main power supply can only be achieved
by disconnecting the mains plug or by an external all-pole disconnection
(e.g. a mains / circuit breaker). The mains plug or circuit breaker therefore
has to be freely accessible at all times. Disconnect the mains plug from the
mains during a lightning storm or when the amplifier remains unused or
unsupervised for a prolonged period of time.

The switch initiates start-up by activating the inrush current limiter. As soon
as the power amplifier is connected to the mains power supply, a vol tage
is supplied to both the line-filter and the fused input of the controllable
rectifier.
If a power cut occurs while the amplifier is switched on, it will restart auto-
mati cally once the power supply has been restored. All amplifier settings
prior to the loss of power will be maintained.