P.21

6 SPECIFICA

TION

Frequency response

@ 4 Ω load with 120 W ouptut power

10 Hz – 20 kHz: ± 0,175 dB

THD+N over frequency

@ 4 Ω load with 120 W output power

20 Hz – 10 kHz: < 0,02 %

Damping factor

8 Ω load, 1 kHz and below

> 400

Input impedance

29 kΩ balanced

Amplifier gain

32 dB default (adjustable through DSP)

Maximum analogue differential input level

+20,5 dBu / 8,2 V

RMS

/ 11,6 V

Peak

Level attenuation

Done through DSP in 0,25-dB-steps

Minimum loudspeaker load impedance

Lower values are safe, but out of specification. No performance guarantees

can be given when driving lower impedances than specified.

Z

min

= 2 Ω for Dual-Channel operation

Z

min

= 4 Ω for Mono Bridge operation

Protection circuits

Inrush-current limitation, mains surge overvoltage protection, temperature monitoring of heatsinks,
output DC protection, temperature dependent SOA protection, mains fuse protection, output cur-
rent limitation, thermal limitation

Analogue limiters (HW)

Clip / Underimpendance Limiter, FuseProtect Limiter

Cooling

Two temperature dependent speed-controlled axial fans

LED indicators

LEDs for signal / protect and clip

Input connectors

Two 3-pin XLR female analogue input connectors, pin 2 = hot (inphase)
Two 3-pin XLR male passive loop through connectors
One 3-pin XLR female AES (digital) input connector
One Ethernet connector RJ45

Power output connectors

One 4-pole SPEAKON

®

connector for each output channel (bi-amping possilbe)

Modes of operation

Dual channel (Stereo), mono bridge

Input sources

Analogue, AES

A/D – D/A converters

24 bit / 96 kHz

We reserve the right to make technical alterations without prior notice.