4.8 Filter Cleaning

The air intake on the front of your iD4 amplifier is fitted with a removable
filter system. If the filter becomes clogged, the unit will not cool as effi-
ciently as it should and may result in reduced output levels.

iD4

Filter Assembly

Œ

Foam filter



Front frame

Ž

Screw

! WARNING!

Turn off and disconnect the amplifier from the mains before removing
the front frame.

To clean or replace the filter just slightly unscrew the fixing screw with the
help of a 3 mm allen key. The screw will be held back by a small plastic
spacer on the back of the frame to avoid losing it. Then shift the front
frame slightly to the right. Then you should be able to remove the frame
from the amplifier completely (pull gently to avoid any bending of the front
frame).