P.14, 3 inst alla tion – Camco D-Power 7 User Manual

Page 15

Advertising
background image

D - P O W E R

S E R I E S

D-POWER 7

A

B

Z ≥ 2*Z

min

*Z

min

= 2 Ω

Bottom SPEAKON

Upper SPEAKON

Input
Channel A

Input
Channel B

USER MANUAL
D-POWER 7

P.14

3.8.4 Mono Bridge Operation

One-channel mono bridged operation.

The second channel processes the same input signal, but with reversed
phase. The (single) load is connected between the two positive channel
outputs using a suitable connected SPEAKON

®

connector. While the total

output of the ampli fier remains the same, both the available output volt-
age and the minimum impedance that can be connected are doubled, as
compared with stereo operation. Only channel A-Input is active – turn the
volume on channel B down to zero.

WARNING !
In Mono Bridge mode RMS output voltages are as high as 230 V. Wir-
ing to the speaker loads must conform to NEC Class 3 safety stand-
ards or its equivalent that meets all national and local electric codes.
All customer specific cables may only be manufactured by qualified
suppliers/personnel. All cabeling or rewiring work must be carried out
by qualified personnel
.

3.8.5 SPEAKON

®

Connection

Both SPEAKON

®

connectors are connected to channel A and channel B

outputs. The pin configuration of the SPEAKON

®

connectors is as follows:

Upper SPEAKON

®

: Pin 1+

Channel A signal

Pin 1-

Channel A ground

Pin 2+

Channel B signal

Pin 2-

Channel B ground

Bottom SPEAKON

®

: Pin 1+

Channel B signal

Pin 1-

Channel B ground

Pin 2+

Channel A signal

Pin 2-

Channel A ground

WARNING!
SPEAKON

®

connectors marked with the lightning flashes indicate

high vol tages that are potentially life threatening.

Wiring to these terminals requires installation by an instructed person
or the use of ready-made leads or cords.

Custom wiring should only be carried out by qualified personnel.

3 INST

ALLA

TION

Advertising