Optimum performance of the extractor
hood:
❑ Short, smooth extraction pipe.
❑ As few pipe bends as possible.
❑ Largest possible pipe diameter (prefera-

bly 150 mm ø) and large pipe bends.

Round pipes:

We recommend
for single-motor model,
inner diameter of at least 120 mm
for double-motor model.
inner diameter of at least 150 mm

Flat ducts must have an inner cross-

section equivalent to round pipes
which have an inner diameter of
120/150 mm.
120 mm l approx. 113 cm

2

150 mm l approx. 177 cm

2

If pipe diameters differ: use sealing

strip.

❑ Ensure an adequate air supply for

exhaust-air mode.

Pipe connection

Extractor hoods with 120 mm Ø air
outlet:

100 mm Ø extraction pipe
❑ Insert the reducing connector (see optio-

nal accessories on the last page) into the
air-pipe connector and then attach the
exhaust-air pipe.

120 mm Ø extraction pipe
❑ Attach the exhaust-air pipe directly to

the air-pipe connector.

Extractor hoods with 150 mm Ø air
outlet:

150 mm l extraction pipe
❑ Screw the reducing connector (see

optional accessories on the last page)
onto the air outlet.

❑ Attach the extraction pipe to the redu-

cing connector.

150 mm l extraction pipe
❑ Attach the exhaust-air pipe directly to

the air outlet..

If a one-way flap has been fitted, con-

duct a performance test.

Extractor hoods with rectangular air
outlet:
❑ Screw the enclosed

air-pipe connector

over the air outlet.

Recirculated
air mode

❑ The air cleaned by an additional activa-

ted carbon filter is conveyed back into
the room.

❑ In recirculated air mode the exhaust ope-

ning must be protected by a grille (see
optional accessories on the last page) in
order to prevent a mechanical or electri-
cal hazard.