5.3 - Presetting of wheel dimensions

5.3.1 - Automatic presetting

The screen appears upon removing the distance + diameter gauge.
The “dimension acquired” message is indicated by the inside correction weight symbol, which changes from blue to
red.

5.3.1.1 - Standard wheels

Remove the gauge and position it corresponding to the correction zone. Wait for the weight symbol on the screen
to pass from blue to red.
If the acoustic signal is enabled (see

ACOUSTIC SIGNAL

), the acquisition of the dimensions is accompanied by a

“beep”.
Set the distance+diameter gauge to the rest position.
The current width value is displayed inside the tyre.

- Set the nominal width, which is normally shown on the rim, or measure the width “b” with