Temperature register, D chapter, Table 126: csr: temperature – ALLIED Vision Technologies Stingray F-504 User Manual

Page 293

Advertising
background image

Configuration of the camera

STINGRAY Technical Manual V4.4.4

291

Temperature register

The temperature is implemented with Presence_Inq=1 (available) and
ON_OFF [6] always ON according to IIDC V1.31:

From -10 °C to +65 °C the temperature accuracy is: +1.5 °C / -2.0 °C

Register

Name

Field

Bit

Description

0xF0F0082C

TEMPERATURE Presence_Inq

[0]

Presence of this feature:

0: N/A

1: Available

Abs_Control

[1]

Absolute value control

O: Control with value in the value field

1: Control with value in the absolute value
CSR

If this bit=1 the value in the value field has
to be ignored.

---

[2..5]

Reserved

ON_OFF

[6]

Write: ON or OFF this feature

Always 1

0: OFF

1: ON

---

[7..19]

Reserved

Value

[20..31] Temperature at the present time (read only)

Read out temperature value and divide by
10: this is the temperature at sensor in
degree Celsius.
Info: 50 °C at sensor is approximately 45 °C
at camera housing. So never run the camera
with more than 50 °C at sensor.

min. displayed temperature: -55 °C

max. displayed temperature: 150 °C

Increment: 0.25 °C/step

Table 126: CSR: Temperature