Advanced register: frame counter, Table 162: advanced register: frame counter – ALLIED Vision Technologies Stingray F-504 User Manual

Page 334

Advertising
background image

Configuration of the camera

STINGRAY Technical Manual V4.4.4

332

Advanced register: frame counter

The frame counter feature is controlled by the following advanced feature
register:

Having this feature enabled, the current frame counter value (images read
out of the sensor, equivalent to # FrameValid) will be inserted as a 32-bit
integer value into any captured image.

Setting the Reset flag to 1 resets the frame counter to 0: the Reset flag is
self-cleared.

Additionally there is a register for direct read out of the frame counter value.

Note

Different to Marlin SIS:

Register 610 is only to be used to reset the frame coun-
ter.

Register

Name

Field

Bit

Description

0xF1000610 FRMCNT_STAMP

Presence_Inq

[0]

Indicates presence of this feature
(read only)

Reset

[1]

Reset frame counter

---

[2..31]

Reserved

0xF1000614 FRMCNT

[0..31]

Frame counter

Table 162: Advanced register: Frame counter

Note

The 4 bytes of the frame counter value will be inserted as
the 5th to 8th byte of a line.

Advertising