Analog Way Axion2 User Manual

Page 41

Advertising
background image

If you are working with an 8x4 matrix (8 in, 4 out), you will need

to define the links between the slave device and the matrix for the

Axion2

to route signals properly.

1/

Press Edit Inputs to open the Inputs page, then select Matrix

Mapping.

2/

Select Input 1 from the dropdown menu, and in the Linked to

Matrix dropdown menu, select your matrix.

3/

In the Matrix Output dropdown menu, select your output

connection.

4/

Repeat steps for Inputs #2 to #4 (matrix outputs #2 to #4).

5/

Press the

[OK]

button to return to the Screen Setup page.

So far, you have set a series of links between your slave device and

a matrix, but you are still limited to the slave device’s input switching

(source #1 to slave device input #1, source #2 to slave device input

#2 and so on). To change this, proceed as follows:

1/

Press Edit Sources to open the Source Setup page, and set

the source Type to Live.

2/

In the Main/Preview section, press

[SOURCE]

button

1, and

press Edit if you wish to rename it.

3/

In the Linked to Matrix dropdown menu, choose the matrix

entered previously, then the type of signal coming from the

matrix.

4/

In the Matrix Input dropdown menu, select the Matrix Input

number you like.

5/

Repeat steps for sources #2 to #8.

6/

Press the

[OK]

button to return to the Screen Setup page.

6-2. MATRIX SETUP EXAMPLE

39

Advertising