*S election of installation positions for indoor unit*

* To be installed at the position w here the air delivered from the unit can reach every corner of

the room ;

* To avoid being affected by the outdoor air;

* To avoid blockage to the air inlet or outlet of the unit;

* To avoid too m uch oil sm oke or steam ;

* To avoid possible generation, inflow , lingering or leakage of flam m able gases;

* To avoid high-frequency facilities (such as high frequency arc w elders, etc.);

* To avoid the places w here acid solutions are frequently used;

* To avoid the places w here som e special sprayers (sulfides) are frequently used.

* N ot to install a fire alarm ing device near the air outlet of the unit (during operation, the fire alarm

device m ight be erroneously triggered by the w arm air from the unit);

IN STALLATIO N & R EPAIR G U ID E

Split W all-M ounted Air C onditioner

Above 100m m (4")

Left side: 150m m (6")

and above

R ight side: 150m m (6")

and above

C eiling

W all hanging plate

ground

2300m m (7'

6")

and above

* M ake sure of enough space for installation and m aintenance.

* To take into consideration the operational convenience and safety in installation, it is recom m ended

to ensure enough space betw een the unit and the w alls.

* H eight lim its of indoor and outdoor units.

* Either the indoor unit or the outdoor unit can be higher, but the height difference m ust com ply the stated

requirem ents.

* Try to reduce the bending of the piping line as m uch as possible so as to avoid possible negative im pacts upon the

perform ances of the units.

Indoor unit

outdoor

unit

5m (16'

5")m ax.