Installation fixture of indoor unit, Installation of w all-m ounting plate, Installation of indoor unit – Amcor UCHW-H09AF2 User Manual

Page 16

Advertising
background image

3

*

Installation fixture of indoor unit

*

IN STALLATIO N & R EPAIR G U ID E

Split W all-M ounted air conditioner

Pipelines can be connected in the directions of****

****and

*

as indicated in Fig.1. W hen the pipelines

are connected to the directions of***and

*

, a groove

for the pipes has to be opened at the proper place on

the base stand.

*

R ear outlet

*

Left rear outlet

*

Left outlet

*

R ight outlet

*

Bottom outlet

Fig.1

1.Installation of w all-m ounting plate

Fix the w all-m ounting plate firm ly on the w all w ith screw s.

M ake sure of the leveling of the plate. Slanted w all-m ounting

pl

ate m i

ght j

eopardi

ze the sm ooth di

scharge of the condensed

w ater.

2.D rill holes on the w all

3.Installation of drain pipe

Install the pipelines of the indoor unit in accordance w ith

the direction of the w all holes. W rap tightly the drain pipe

and the pipelines w ith tape. M ake sure that the drain pipe

is underneath the pipelines. (Fig.3) (W hen the drain pipe

passes the room interior, som e condensed w ater m ight

occur to its surfaces if the hum idity is very high).

4.Installation of indoor unit

Pass the connection w ires, connecting pipelines and drain

pipe through the w all hole. H ang the indoor unit on the

hooks at the top of the w all-m ounting plate so that the

hooks at the bottom of the indoor unit m atch the hooks of

the w all-m ounting plate. (Fig.4)

Fig.2

Fix w ith a tape

W all cap

W all pipe

Interior

Exterior

5-10m m low er

(1/5-2/5")

W all

Fig.3

Pipelines of indoor unit

D rain pipe

R ear pipe

Bottom hooks

H ook supports

Top hooks

Fig.4

D rill holes at places slightly below the w all-m ounting plate,

w ith hole diam eter of 65m m (2-3/5") and the outer edge of

the hol

e 5-10m m (1/5-2/5") l

ow er (Fi

g.2) so that the condensed

w ater can sm oothly flow out. C ut the w all penetrating pipe

to proper length according to the thickness of the w all (3-

5m m (1/10-1/5") longer than the w all thickness) and insert

the pipe as indicated in Fig.2.