C onnection of pow er cable, Finishing touches, Test running – Amcor UCHW-H09AF2 User Manual

Page 20: Is the unit installed correctly

Advertising
background image

7

*

C onnection of pow er cable

*

IN STALLATIO N & R EPAIR G U ID E

Split W all-M ounted air conditioner

1.R em ove the draw er of the outdoor unit.

2.N on-quick coupler:connect the indoor pow er and control

w ires w ith the m atched outdoor w ires in accordance

w ith the electric schem atic diagram and m ake sure

that the connection is firm ly done

Q uick coupler:directly connect quick cable couplers w ith

indoor and outdoor quick cable couplers after disassem bly

of the outdoor unit connecting box cover

w ire pressing plate

D raw er

screw

3.U se a press plate to fix the w ires firm ly,and re-install

the draw er.

N ote:D o not connect the w ires in a w rong w ay,otherw ise electric m alfunctions w ill be caused and

even dam ages to the units w ill occur.The appliance shall be installed in accordance w ith national

w iring regulation.If the supply cord is dam aged,it m ust be replaced by the m anufacturer or its service

agent or a sim ilarly qualified person in order to avoid a hazard.The plug shall be accessible after

installing the appliance.If the m odel have not plug that a sw itch w hich have a contact separation

of at least 3 m m (1/10") in all poles shalled be added in fixed w iring.

* U se therm al tube to w rap the joints and w rap the tube tightly w ith ethylene tapes.

* Fix the w rapped pipelines on the exterior w all w ith clam ps.

* Fill in the gaps left over by the pipeline hole and w all hole to prevent rain-w ater from entering.

*

Finishing touches

*

* C onnect to the pow er source,check if the function selection keys on the rem ote controller are
w orking properly.

* C heck if the room tem perature adjustm ents and tim er settings are w orking properly.

* C heck if the drain is sm ooth.

* C heck if there is any abnorm al noise or vibration during operation.

* C heck if there is leakage of refrigerant.

*

Test running

*

Fig.9

Fig.10

(Fig.9).

(Fig.10).

*

Is the unit installed correctly?

*

*Isn'

t there anything w hich prevents ventilation or obstructs operation in front of the indoor unit ?

D o not install the unit follow ing place .

*Inflam m able gases m ay leak .

*O il splashes a lot .

*In case w here the uni

t i

s used i

n such pl

aces as poi

sonous or sul

try gases are generated or seasi

de

district exposed to sea breezes corrosion m ay cause m alfunction . C onsult w ith your distributor .

*Ai

r condi

ti

oner body and rem ote control

l

er m ust be I m (39-3/4") or m ore aw ay from a TV or a radi

o.

D rain the dehum idified w ater from the indoor unit to a place w hich drains w ell .

*W hen installing the unit , choose a place w hich can stand the w eight of the unit w ell and does
not increase the operation noise or vibration . Especially w here there is a possibility that vibration
be transm itted to the house , fix the unit by inserting attached vibration -proof pads betw een the
unit and fittings .

*Suitable Installation Position

*Pay attention to operation noise