Evmu – EBARA EVMU User Manual

Page 12

Advertising
background image

Ebara Stainless Steel Vertical Multistage

EVMU

Instructions and Operation

Ebara

Fluid Handling

www.pumpsebara.com

12

(t) 803 327-5005 • (f) 803 327-5097

rev. 11/10

6b removing the motor from models:

EVMU3 13- EVMU 3 18

EVMU 32 All Sizes (Except EVMU32 1)

EVMU5 7 – EVMU 5 17

EVMU 45 All sizes

EVMU10 4 – EVMU 1016

EVMU 64 All Sizes

EVMU18 3 – EVMU 18 11

(1)

Following general safety and electrical instructions, disconnect the power to the motor and
remove power cords.

(2)

Loosen and remove the four motor bolts.

(3)

Attach a strong sling or chains to the motor lifting lugs or eyebolts to ensure that the motor is
balanced when lifted vertically.

(4)

Slowly lift the motor off the pump assembly being careful to retain the shaft key. If the motor
does not slide easily out of the coupling do not raise the pump into the air, dropping the pump
end can cause damage. Fix the pump base to the floor or bench and lift motor again.

Section 7 – General Pump Maintenance and Disassembly Instructions

Disassembly Tips
• Before beginning, it is recommended that tape or some other method of marking be used to

make markings on the outer “can” assembly to indicate orientation, such as “top” and “bottom”.

• Next, make corresponding alignment markings that indicate where the bottom of the can and

lower casing assembly meet. Also make another marking to indicate where the top of the can
and lower portion of the cast iron motor support meet.

• Always inspect for damage of other components and clean any debris that you may find during

maintenance procedures.

• Cross sectional views of the pumps are a good reference for these procedures and can be

found starting on page 22.

7a replacing the Mechanical Seal

EVMU3 2 – EVMU3 12

EVMU10 2 – EVMU10 3

EVMU5 2 – EVMU5 6

EVMU18 2

EVMU 32 1

(1)

Isolate the pump by closing isolation valves on the suction and discharge lines.

bEFOrE PrOCEEDING TO STEP 2, PLEaSE rEaD THE CaUTION bLOCK bELOW.

Extreme caution should be exercised in this operation since the pump is under system pressure
at this point.

relieve pressure before performing work on the pump.

Use a pressure bleed valve in hot water applications where water temperature could cause
physical injury.

CaUTION

!!

Advertising