Code Faults

Cause
of the
fault

Description

Checking / solution

L30

DEF.FLUE GAS
PRESSURE

PCU

The flue gas pressure switch

opened 5 times in 24 hours.

4

Contact the professional who takes care of

maintenance of the appliance

L31

DEF.SMOKE.TEMP

PCU

The maximal smoked temperature

is exceeded of 5 times in 24 hours.

4

Contact the professional who takes care of

maintenance of the appliance

L32

DEF.OUTLET S.

PCU

The boiler flow sensor has short-

circuited

Bad connection

Sensor fault

4

Contact the professional who takes care of

maintenance of the appliance

L33

DEF.OUTLET S.

PCU

The boiler flow sensor is on an open

circuit

Bad connection

Sensor fault

4

Contact the professional who takes care of

maintenance of the appliance

L34

BACK S.FAILURE

PCU

The return temperature sensor has

short-circuited

Bad connection

Sensor fault

4

Contact the professional who takes care of

maintenance of the appliance

L35

BACK S.FAILURE

PCU

The return temperature sensor is

on an open circuit

Bad connection

Sensor fault

4

Contact the professional who takes care of

maintenance of the appliance

L36

DEF.FLAME LOS

PCU

3 flame losses during a heating

demand

4

Contact the professional who takes care of

maintenance of the appliance

L37

SU COM.FAIL

PCU

Communication breakdown with

the safety box

Bad connection

4

Contact the professional who takes care of

maintenance of the appliance

L38

PCU COM.FAIL

PCU

Communication failure between the

PCU and SCU PCBs

Bad connection

SCU PCB not connected or faulty

4

Contact the professional who takes care of

maintenance of the appliance

L39

BL OPEN FAIL

PCU

The BL inlet opened for a short time Bad connection

External cause

Parameter incorrectly set

4

Contact the professional who takes care of

maintenance of the appliance

L250 DEF.WATER MIS.

PCU

The water pressure is too low

Hydraulic circuit incorrectly vented

Water leak

Measurement error

4

Top up with more water if necessary

4

Reset the boiler

L251 MANOMETRE FAIL

PCU

Fault on the water pressure sensor Wiring problem

Failure water pressure switch

Sensor pcb defect

4

Contact the professional who takes care of

maintenance of the appliance

D03
D04

OUTL S.B FAIL.
OUTL S.C FAIL.

SCU

Circuit B flow sensor fault

Circuit C flow sensor fault
Remarks:

The circuit pump is running.

The 3-way valve motor on the

circuit is no longer powered and can

be adjusted manually.

Bad connection

Sensor fault

4

Contact the professional who takes care of

maintenance of the appliance

6. Troubleshooting