Code Faults

Cause
of the
fault

Description

Checking / solution

D27

PCU COM.FAIL

SCU

Communication failure between the SCU and PCU PCBs

4

Contact the professional who takes care of maintenance of the appliance

D37

TA-S SHORT-CIR

SCU

The Titan Active System® is short-circuited

4

Contact the professional who takes care of maintenance of the appliance

Remarks:

Domestic hot water production has stopped but can nonetheless be restarted using

key r.

The tank is no longer protected.

If a tank without Titan Active System® is connected to the boiler,check that the

TAS simulation connector (delivered with package AD212) is fitted to the sensor

card.

D38

TA-S DISCONNEC

SCU

The Titan Active System® is on an open circuit

4

Contact the professional who takes care of maintenance of the appliance

Remarks:

Domestic hot water production has stopped but can nonetheless be restarted using

key r.

The tank is no longer protected.

If a tank without Titan Active System® is connected to the boiler,check that the

TAS simulation connector (delivered with package AD212) is fitted to the sensor

card.

D99

DEF.BAD PCU

SCU

The SCU software version does not recognise the PCU connected

4

Contact the professional who takes care of maintenance of the appliance

6. Troubleshooting

AFC 18 - AFC 24 - AFC 30

37

09/01/2014 - 300026440-001-03