Selecting the operating mode – DE DIETRICH AWHP-2 MIT-IN-2 iSystem User Manual

Page 19

Advertising
background image

Menu C
Parameter

Adjustment range Description

Factory setting

WATER T.NIGHT

(2)

10 to 80 °C

Set tank temperature, night programme

10 °C

TEMP.TANK AUX

(2)

10 to 80 °C

Desired domestic hot water temperature in the auxiliary

circuit

55 °C

WATER T.NIGHTAUX

(2)

10 to 80 °C

Desired domestic hot water temperature in the auxiliary

circuit for the night program

10 °C

DHW A TEMP.

(2)

10 to 80 °C

Desired domestic hot water temperature in circuit A

55 °C

WATER T.NIGHT.A

(2)

10 to 80 °C

Desired domestic hot water temperature in the tank

connected to circuit A for the night program

10 °C

TEMP.SOL.TANK

(2)

10 to 80 °C

Temperature of the hot water produced by solar power (TS) 55 °C

SWIMMING P.T.B

(2)

0 to 39 °C

Desired temperature for swimming pool B

20 °C

SWIMMING P.T.C

(2)

0 to 39 °C

Desired temperature for swimming pool C

20 °C

(1) The parameter is only displayed if the corresponding circuit can handle cooling.

(2) The parameter is only displayed for the options, circuits or sensors actually connected.

4.3.2.

Selecting the operating mode

To select an operating mode, proceed as follows:
1. Press the MODE key.
2. To select the desired parameter, turn the rotary button.
3. To modify the parameter, press the rotary button.

To go back to the previous display, press the key j.

4. To modify the parameter, turn the rotary button.
5. To confirm, press the rotary button.

To cancel, press key h.

Menu MODE
Parameter

Adjustment range Description

Factory setting

AUTOMATIQUE

The comfort ranges are determined by the timer programme.

DAY

7/7, xx:xx

Comfort mode is forced until the time indicated or all the time (7/7). Present time + 1

hour

NIGHT

7/7, xx:xx

Reduced mode is forced until the time indicated or all the time

(7/7).

Present time + 1

hour

HOLIDAYS

7/7, 1 to 365

The antifreeze mode is active on all boiler circuits.
Number of days’ holiday: xx

(1)

heating OFF: xx:xx

(1)

Restarting: xx:xx

(1)

Present date + 1

day

SUMMER

The heating is off.

Domestic hot water continues to be produced.

(1) The start and end days and the number of days are calculated in relation to each other.

(2) The parameter is only displayed if a room sensor is connected.

MODE

C002267-A

AWHP-2 MIT-IN-2 iSystem

4. Operating the appliance