CAMERA ADJUSTMENT

CAMERA ADJUSTMENT

ON: Make motion areas visible, OFF: Hide motion areas

ENABLE

Press enter to access the

“dead band setting”

screen, on-screen cursor moves in response to the

inputs Left, Right, Up and Down to set the sensing area,

or dead band for specified blocks. This allows you to

specify and set an area of motion which is not

rectangular in shape.

Press and hold SET button 3 seconds to exit.

MOTION AREA:

ON / OFF Enable / Disable Area No.

AREA SEL: 1/4 / 2/4 / 3/4 / 4/4. Selects motion area number.

TOP:

Set the top side of the monitoring frame selected by the AREA SEL

parameter.

BOTTOM: Set the bottom side of the monitoring frame selected by the AREA

SEL parameter

LEFT:

Set the left side of the monitoring frame selected by the AREA SEL

parameter.

RIGHT:

Sets the right side of the monitoring frame selected by the AREA SEL

parameter

CAMERA ID

OFF / ON

Camera ID shows a name on the screen as chosen.

CAMERA TITLE SETUP

CAMERA

ABCDEFGHIJKLMNOPQRSTUV

WXYZ0123456789-!#$%&’

()_`.:;<=>@^*./^*X+/

CHR1 CHR2



CLR POS

RETURN

Use Up/Down/Left/Right to move around. CHR1/2 changes the selection fonts to
alternative selection, CLR will clear info. POS allows position change.

LL

PHASE

326

RETURN

SYNC

INT / LL

Video synchronization displayed

INT(Internal) or LL (Line Lock)

Note: Shows INT with DC only model.

And LL setting for camera model

when connected to a AC supply.

PHASE:

000-524

Adjust the phase in the vertical direction when the line

lock mode is available.

CAMERA RESET

 

This will reset all settings for all menus to manufacturer

defaults. This allow you to return to shipped settings

from the manufacturer.

EXIT / SAVE ALL

•  EXIT

Exit OSD menu.

•  SAVE ALL

Saves the settings to camera

Refer to the following table if you are experiencing trouble with your camera.