Dimensions, Troubleshooting – eLine Technology SIP-D User Manual

Page 35

Advertising
background image

59

60

Troubleshooting

8. DIMENSIONS

Units: mm /&Inch

Because our products are subject to continuous improvement, product
design and specifications without notice and without incurring any obligation.
E&O.E.

112 mm

4.4"

39 mm

1.5"

115 mm

4.5"

27 mm

1.1"

137?

123?

100?

7 mm

.28"

130 mm

5.1"

Troubleshooting

9. TROUBLESHOOTING

Can’t find the camera IP address using NVMS or other software:

• Make sure Ethernet and/or DC power cables are correctly connected to

the camera.

• Make sure the PoE switch or DC power source meets the camera’s power

requirements (class 3 PoE / 450mA / 5.4W / 12V). If using PoE, make sure

the PoE switch is powered on.

• Make sure the PC is on the same network as the camera. Ping the

camera’s IP address. On your PC, go to

Start > Programs > Accessories

> Command Prompt. Type ping then the camera’s local IP address and

press

Enter. If you get the message “Request timed out,” PC and camera

are not on the same network or camera is not connected. Camera is

connected if you receive replies.

• Connect the BNC test cable to the camera and the other end to a test

monitor. The monitor display shows the camera’s IP address. A default

IP address of 192.168.0.120 may mean that the camera cannot obtain an

IP address from the router. Check the Ethernet/power connections and

router configuration.

• Camera set for static IP mode using an incorrect IP address. By default,

the camera is set for DHCP mode, which means it will automatically obtain

an IP address from your router. Reset the camera to factory default

settings by removing the camera cover and pressing the reset button for

5 seconds or more.

Can’t connect to the camera on a web browser using local IP address:

• See steps above.

• Verify the camera’s local IP address using one of the methods listed in

“4. Finding the Camera’s IP Address” on page 9.

eLineTechnology.com