Tts-1 rear panel – Biamp TTS-1nc User Manual

Page 6

Advertising
background image

6

TTS-1 REAR PANEL

Device ID
The rotary ID switches are located on the back of the TTS-1 and give the unit a unique Device ID. The switches are in hexadecimal format.
All TTS-1 units must have a unique Device ID to function properly within a Vocia Paging World (i.e., it is not possible to have two TTS-1
units with the same Device ID of hex 07). To assign a Device ID of hex 07, turn the LSB switch to 7 and leave the MSB switch on
0. To create an ID of hex B7, turn the LSB switch to 7 and turn the MSB switch to B. Device ID switches should be set using a 0.1 inch
(2.5mm) to 0.12 inch (3.0mm) flat blade screwdriver. More information on setting IDs and the hexadecimal numbering scheme used in
Vocia can be found in the Vocia Help File.

Please note: Changes made to the Device ID while connected to the network require a power cycle in order to take effect.

Network Connection
The TTS-1 has four RJ45 Ethernet connectors located on the rear panel (Control, Vocia Network, and Spare). Each connector has two
green LEDs, which display Ethernet Link (left LED) and Activity (right LED).

LAN-1 Connector (Control)
This port connects the TTS-1 to a control network. This should be separate to the LAN that is being used by the CobraNet port either
physically or through the use of managed switches and VLANs. The TTS-1 can be configured in the Vocia software via this port, and as
such it should be connected to the same network as any Vocia Message Server 1 (MS-1) devices and computer running Vocia Software.
The Default IP address is 192.168.1.201.

LAN-2 Connector (CobraNet)
This port is used to communicate with local Vocia devices and as such should be connected to the same network as the local Vocia sys-
tem. The data from the CobraNet network should be placed on its own LAN, either physically or through the use of managed switches and
VLANs.

LAN-3 and LAN-4 Connectors (Spares)
These ports are inactive at this time.

O

Model TTS-1

BIAMP SYSTEMS

MSB

LSB

Device ID

LAN1: Control

LAN2: Cobranet

TM

LAN3: Spare

LAN4: Spare

AC Power

Entrance (IEC)

USB Ports

RS232 Port

LAN-1

(control)

LAN-3

(Spare)

Device ID

LAN-2

(CobraNet)

LAN-4

(Spare)