PHYSICAL CONNECTIONS

RS-232 Nurse Call Physical Connection
The TTS-1nc allows interfacing to Nurse call systems via RS-232 and supports the TAP protocol. Currently the TTS-1nc supports Rauland
Responder 4 and 5 natively. Two connection modes are supported. Active Mode is supported where the TTS-1nc and Nurse call system
are the only devices used. This provides a fully monitored connection between the Nurse call system and the TTS-1.
Passive mode is supported where existing connections already exist between the Nurse Call system and a third party system. This pro-
vides an unmonitored connection between the Nurse call system and the TTS-1.

Wiring requirements of Active Connection

Wiring requirements of Passive Connection

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

Not Connected

CD

RxD

TxD

DTR

SG

DSR

RTS

CTS

RI

Nurse Call

System

Third

Party

System

D-9 Female

CD

RxD

TxD

DTR

SG

DSR

RTS

CTS

RI

D-9 Female

1

2

3

4

5

6

7

8

9

CD

RxD

TxD

DTR

SG

DSR

RTS

CTS

RI

D-9 Female

TTS-1

Passive

Mode

The enclosed diagram is indicative. Connection wiring may vary depending on the interfacing hardware. Suitable isolating and 

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

Not Connected

CD

RxD

TxD

DTR

SG

DSR

RTS

CTS

RI

Nurse Call

System

TTS-1

Active

Mode

D-9 Female

CD

RxD

TxD

DTR

SG

DSR

RTS

CTS

RI

D-9 Female