Typical manual wastewater installation – BJM Pumps SX75CSSF-575T User Manual

Page 9

Advertising
background image

9

PUMP OPERATION

This pump is designed to handle dirty water that contains some solids. It is

not designed to pump volatile or flammable liquids. Do not attempt to pump any liquids which
may damage the pump or endanger personnel as a result of pump failure.

Do not operate this pump where explosive vapors or flammable

material exist. Death or Serious injury will result.

TYPICAL MANUAL WASTEWATER INSTALLATION

NOTE: Maximum recommended starts should not exceed 10 times per hour.


All S-F & SX-F models

are provided with a 33’ (10 m) power cord. NEVER splice the power

cable due to safety and warranty considerations. Always keep the lead end dry.
Note: 208V, 230V, 460V & 575V three phase units do not have a plug and have to be provided
separately.

Do not alter the length or repair any power cable with a splice. The pump

motor and cable must be completely waterproof. Damage to the pump or personal injury may
result from alterations.

For manual operation: 208, 230, 460 & 575 volt: Connect directly to the power source or
control box. Check the direction of the rotation. Tilt the pump and start it. It should twist in the
opposite direction of the arrow (on pump).