Installation

7.1.5. Fluid connection AirLINE Quick

Air discharge connection R/S

Example of
connection adapter

Supply connection P

Fig. 13: Fluid connection AirLINE Quickk

Procedure:

Screw connection adapter G1/4" or NPT 1/4" to connections P
and R/S.

NOTE!

Risk of leakage if screw connection is too tight!
• When fitting the fluid connection adapters to the connections

P, R/S, observe the max. torque of 12 Nm. In doing so, counter

with a suitable tool to prevent the connections from turning!

7.2. Fluid deinstallation

NOTE!

Irreversible damage to the seal in the thread of the screw
connection!
• When loosening the connection adapters, use a suitable tool to

prevent the corresponding supply or air discharge connection

from turning.

7.3. Electrical Installation

DANGER!

Risk of injury due to electrical shock!
• Before reaching into the device or the equipment, switch off the

power supply and secure to prevent reactivation!

The electrical installation of the AirLINE system corresponds to the
installation of the decentralized peripheral device (depending on the
relevant cooperation partner Siemens, Wago, Phoenix or Rockwell).
Refer to the manuals provided by the cooperation partners for a more
detailed description.