Assembly

5.3.2. Fluid connection

Type 6524

3/R

X*

2/A

1/P

Type 6525

X*

5/R

4/A

1/P

2/B

3/S

Design the pressure supply
with the largest possible
volume!

X* - pilot control exhaust air

Fig. 2:

Fluid connection. Types 6524 and 6525

5.3.3. Fluid and electrical connection

Type 6524
(2 x 2/3-way valve)

12

14

- Pin coil 12

controlled via bit “n+1”

- Pin coil 14

controlled via bit “n”

+ Pin

X*

5/R

4/A

1/P

2/B

3/S

Bit “n+1”

Bit “n”

Observe pin
assignment!

X* - pilot control
exhaust air

Hand lever
assignment

Fig. 3:

Fluid and electrical connection. Type 6524

6. ASSEMBLY

6.1. Safety instructions

DANGER!

Risk of injury from high pressure in the equipment!
• Before loosening lines or valves, turn off the pressure and vent

the lines.

Risk of injury due to electrical shock!
• Before reaching into the device or the equipment, switch off the

power supply and secure to prevent reactivation!

• Observe applicable accident prevention and safety regulations

for electrical equipment!

WARNING!

Risk of injury from improper assembly!
• Installation may only be carried out by authorized technicians with

the appropriate tools!

Risk of injury from unintentional activation of the system and
uncontrolled restart!
• Secure system from unintentional activation.
• Following assembly, ensure a controlled restart.