Technical data – Burkert Type 8644 User Manual

Page 7

Advertising
background image

7

Technical data

5. TECHNICAL DATA

5.1. Conformity

The system AirLINE type 8644 conforms with the EC Directives
according to the EC Declaration of Conformity.

5.2. Standards

The applied standards, which verify conformity with the EC Direc-
tives, can be found on the EC-Type Examination Certificate and / or
the EC Declaration of Conformity.

5.3. General Technical Data

Technical Data

Pilot valve type 0460,

6524, 6525

Pilot valve type 0461,

6526, 6527

Pressure range

Vac. up to 10 bar

Vac. up to 10 bar

Operating
voltage

24 V DC

24 V DC

Voltage tolerance +20 % / -15 %

(when using
Type 0460: ± 10 %)

+20 % / -15 %
(when using
Type 0461: ± 10 %)

Ambient
temperature

0 ... +55 °C
(when using Type 0460 and 0461: 0 ... +50 °C)

5.3.1. Rating plate

MADE IN GERMAN

Y

W14UN

450000Y

24 V DC 1W

PN 2,5 - 7 bar

6525 H 4,0

Type

Operating principle

Orifice

Identification number

Voltage (±10 %), capacity

Pressure range

Fig. 1:

Location and description of the rating plate

english

Type 8644

Advertising