Burkert Type 8644 User Manual

Page 25

Advertising
background image

8644/Rockwell - 21

S

YSTEM

D

ESCRIPTION

In its minimal configuration, the system consists of field bus nodes and the valve block.

The closing plate protects both the system and persons from improper contact.

Terminals can be arranged before and after the valve block.

System description

Procedure for changing the electrical function module:

Switch off the electricity and compressed air supplies to the AirLINE
system

Unscrew fixing screws of the valves with a screwdriver

Pull valve off valve plug

Keep dirt away from flange seal and O-ring (3/2 valve)

Loosen the functional module at the rear latching mechanism and pull
away upwards from the distributor module (backplane bus) without tilting it

Set the new functional module vertically on the distributor module (back-
plane bus) and press downwards until it can be heard to latch in

Place valve with clean inserted flange seals/O-rings onto the valve position
and tighten the screws according to the adjacent assembly drawing

ACHTUNG!

Do not introduce foreign parts into the basic module (24V supply bus)-

-> Risk of short circuit

20 Ncm

20 Ncm

30 Ncm

30 Ncm

Advertising