Type 8660 control center – Burkert Type 8660 User Manual

Page 26

Advertising
background image

Type 8660 Control Center

________________________________________________________

- 26 -

7.3.7 Switching the fresh air / circulation air flap on and off in ZE

(only with Control Center 2 and 3)

Pressing the key

causes the motor of the fresh air / circulation air flap to run for 60 seconds. If the

LED in the key is lit up, the flap is in the Circulation position. If the LED is switched off, the flap is in

the Fresh air position.

7.4 Operating Options in Operational Mode Motor on (ME)

7.4.1 Overview of the operating options in ME

In the operational mode Motor on, depending on which apparatus variation is used (Control Center 1,

2 or 3), the following operating options can be executed:

Activating the front box flaps to change the air flow direction

Activating the set point regulator for the driver's seat heater

Switching front box blower levels 1, 2 and 3 on and off

Activating the Defrost function (with blower level 3)

Switching the passenger area floor unit on and off (with Control Center 2 and 3 two heat levels)

Switching the passenger area roof unit on and off (only with Control Center 2 and 3)

Switching the supplementary heater on and off by hand (only with Control Center 2 and 3).

The supplementary heater can only be switched on when the supplementary water pump is

running - when the valve position is > 15%. When the valve position is < 10%, it will be

automatically switched off.

Switching the driver's seat unit (with Control Center 1) or the fresh air / circulation air flap (with

Control Center 2 and 3) on and off

Switching the cooling unit on and off (only with Control Center 3)

Advertising