Type 8660 control center, 11 switching the cooling unit on and off in me – Burkert Type 8660 User Manual

Page 30

Advertising
background image

Type 8660 Control Center

________________________________________________________

- 30 -

7.4.11

Switching the cooling unit on and off in ME

(only with Control Center 3)

At the position which is furthest to the left of the temperature set point regulator is the switch to turn

the cooling unit on and off. Locking the switch in and then out again, switches the unit on. Feedback

is shown on the display. When AC blinks there, it means that the cooling unit has been contacted by

the Control Center. If AC is shown, but it's not blinking, then the cooling unit is switched on. To switch

the cooling unit off, lock the switch in and out once again. If no feedback is registered from the cooling

unit within the first 60 seconds, then the corresponding Control Center output will be deactivated. A

special error message will not appear.

When the motor is switched off, the cooling unit will be automatically out of operation.

Advertising