8

NOTE

Elements / Components sensitive to electrostatic
discharges

• This device contains electronic components sensitive

to electrostatic discharges. They may be damaged
if they are touched by an electrostatically charged
person or object. In the worst case scenario, these
components are instantly destroyed or go out of order
as soon as they are activated.

• To minimise or even avoid all damage due to an elec-

trostatic discharge, take all the precautions described
in the EN 61340-5-1 and 5-2 norms.

• Also ensure that you do not touch any of the energized

electrical components.

English

9

4. GENERAL

INFORMATION

4.1. Manufacturer's address and

international contacts

To contact the manufacturer of the device, use following
address:

Bürkert SAS

Rue du Giessen

BP 21

F-67220 TRIEMBACH-AU-VAL

The addresses of our international branches can be found
on the last pages of this manual.

They can also be found on the Internet under:

www.burkert.com

4.2. Warranty conditions

The condition governing the legal warranty is the con-
forming use of the device in observance of the operating
conditions specified in this manual.

4.3. Information on the Internet

You can find the user manual and technical datasheets
regarding type 1078 or 1077 on the internet at:

www.burkert.com

English

9

10

5.

AREA OF APPLICATION

The timer 1078-1 or 1078-2 is plugged on a solenoid valve
by means of an EN 175301-803 form A fixed connector.

The timer allows for controlling the activation/deactivation
cycle of the solenoid valve.

5.1. General description

5.1.1. Construction

The timer 1078-1 or 1078-2 is a class II control device and
a Type 1 action device (see EN 60730-1 standard).

The timer 1078-1 or 1078-2 is an electronic module enclosed
in a housing with a transparent cover, a cable gland and an
EN 175301-803 female fixed connector, form A, with seal.
The timer is attached to the solenoid valve by means of a
screw.

• The timer 1078-1 is connected to the power supply

through the cable gland, by means of a 3-pole terminal
block in the housing.

• The timer 1078-2 is connected to the power supply

through the cable gland, by means of a 5-pole terminal
block in the housing.

The timer energizes the solenoid valve.

The timer 1078-2 can be configured by means of a configu-
ration module 1077-2, inserted onto the 1078-2 in place of

English

11

its cover.

5.2. Available versions

Device

Supply voltage

Order code

Timer 1078-1

12-24 V DC

060647

24-48 V AC, 50-60 Hz,
24-48 V DC

060621

110-230 V AC,
50-60 Hz

060620

Timer 1078-2

12-24 V DC

060648

24-48 V AC, 50-60 Hz,
24-48 V DC

060629

Configuration module 1077-2 for timer
1078-2

060638

English

11