Burkert Type 1078-2 User Manual

Page 5

Advertising
background image

16

53,5

21

M3x55

Fig. 4: Dimensions [mm] of the 1078-2 combined with

the 1077-2

6.2.2. General

features

Time range (1078-1)
(mechanical adjustment
using the 6 switches N°
1, 2, 3, 6, 7 and 8)

• 0,5 to 10 s (default setting)

• 1,5 to 30 s

• 5 to 100 s

• 0,5 to 10 min.

• 1,5 to 30 min.

• 5 to 100 min.

• 12 to 240 min.

• 0,5 to 10 h

English

17

Time range (1078-2)
(digital adjustment through
module 1077-2)

0,2 s to 9999 h, continuous

Tolerance (1078-2)

1 %

Resolution (1078-2)

• up to 199 s

• up to 199 min.

• up to 99 h

• up to 9999 h

• 10 ms

• 1 s

• 1 min.

• 1 h

6.2.3. Electrical

data

Table 1:

Electrical data of the 1078

Power supply

• 1078-1

• 1078-2

Tolerance 10 %

• 12-24 V DC, max. 2 A

or 24-48 V AC/DC, max
1,5 A or 110/230 V AC,
max 0,5 A

• 12-24 V DC, max. 2 A

or 24-48 V AC/DC, max
1,5 A

Protection against polarity
reversal

No, for devices energized
with a direct voltage

English

17

18

Power supplied to the
solenoid valve

• Version 12-24 V DC

• Version 24-48 V AC/DC

• Version 110/230 V AC

• 12-24 V DC, max. 2 A

• 24-48 V DC, max. 1,5 A

• 110/230 V DC, max.

0,5 A

Clearance and leakage
path

Acc. to VDE 0100

Electrical connection

• Cable diameter

• Cross section of the

wires

Through PG9 cable gland

• 6 to 7 mm

• max. 1,5 mm

2

Table 2:

Electrical data of the 1077-2

Supply voltage

Energized by the 1078-2

Power consumed

5 mW

English

19

7.

INSTALLATION AND WIRING

7.1. Safety information

DANGER

Risk of injury due to electrical voltage.

• Before starting work, make sure that you switch off the

supply voltage and secure it to prevent restarting.

• Do not unscrew the cover of a powered device.
• Observe all applicable accident protection and safety

guidelines for electrical equipment.

WARNING

Risk of injury due to nonconforming installation.

• The electrical installation can only be carried out by

qualified and skilled staff with the appropriate tools.

• Install appropriate safety devices (correctly rated fuse

and/or circuit-breaker).

English