Installation

general Technical data

6.2.

Observe the technical specifications as specified on the
type plate!

Max. delivery pressure:

2.5 bar

(overpressure towards the atmospheric

pressure)

Connections:

3 x rectangular connector

3 x stranded wire 200 mm

(other designs on request)

Type plate

6.2.1.

example:

Housing material

Seal material

Voltage / Type of current

Output

Device designation
Serial number

Date of manufacture
(encoded)

Identification number of the
device

7616 CC PK

M

a

d

e

in

G

e

rm

a

ny

00202784

W16LP

DOSING UNIT

24V DC

5W

S/N 1050

Type

Rating plate description

Fig. 1:

insTallaTiOn

7.

safety instructions

7.1.

Caution!

risk of injury from improper installation!

Installation may be carried out by authorised technicians only

and with the appropriate tools!
Before loosening the lines and valves, turn off the pressure and

vent the lines.
Before reaching into the device or the equipment,

switch off the

power supply and secure to prevent reactivation!
Observe applicable accident prevention and safety regulations

for electrical equipment!

preparatory work

7.2.

Clean the connecting cables

note!

Malfunction due to unfiltered medium!
Crystallised medium or particles in the medium impair the
functionality of the device or result in the unit being destroyed.

Install upstream filter.

(Pore size 50 µm)