English – Burkert Type 7616 User Manual

Page 19

Advertising
background image

19

Dosingsystem(Optional)

Control (1)

Hardware allocation: Control / Dosing unit

Fig. 10:

Control (1) of the dosing unit based on the pre-configured
control frequencies

pin

type

status

description

Error_OUT Output

high

Hardware error, stop in case of
overtemperature

Dln_0

Input

open

Z0: Operation via serial interface; both
dosing units are in standby after start-up

Dln_1

Input

open

Dln_0

Input

Ground

Z1: Operation via serial interface; both
dosing units start with default parameters
(if configured) after start-up

Dln_1

Input

open

Dln_0

Input

open

Z2: Operation via PIN Dln_2 ... Dln_7
(Digital inputs)

Dln_1

Input

Ground

Dln_0

Input

Ground

Z3: Operation via PIN Pot_0 and Pot_1
(Analogue inputs)

Dln_1

Input

Ground

Dln_2

Input

open

If Z2: Dosing unit 1 off

Dln_3

Input

open

Don_2

Input

Ground

If Z2: Dosing unit 1 operates at its pre-
configured frequency 1
(if configured)

Dln_3

Input

open

Dln_2

Input

open

If Z2: Dosing unit 1 operates at its pre-
configured frequency 2
(if configured)

Dln_3

Input

Ground

Dln_2

Input

Ground

If Z2: Dosing unit 1 operates at its pre-
configured frequency 3
(if configured)

Dln_3

Input

Ground

english

Type 7616

Advertising