Burkert Type 7800 User Manual

Page 25

Advertising
background image

27

6.2 Indirect calibration

A value from the following table is to be added to the
default factory calibration value in the display. To re-
set the pump to the factory calibration value, activate
the “DEFAULT” function, see section 4.17.

To use the values, the following must be fulfilled:

• The viscosity and density of the liquid to be dosed

must not differ considerably from water at 20°C.

• A Grundfos installation kit or corresponding foot

valve, injection valve and hose diameter must be
used.

• The length of the dosing hose must not exceed

6 metres.

• The suction lift must lie between 0.1 and 1.5 me-

tres.

Adding the value:

Fig. 25

Pump type

Values to be added to the calibration value at various counter pressures [bar]

0-1

1-2

2-3

3-4

4-5

5-6

6-8

8-10

10-12

12-14

14-16

16-18

7800-

2 1.4 1.1 0.8 0.5 0.2 -0.2 -0.6 -1.2 -1.8 -2.4 -3.0 -3.6

3.5

2.7

2.0

1.2

0.4

-0.4

-1.6

-3.1

-

-

-

-

2.1

1.3

0.4

-0.4

-1.3

-2.1

-3.4

-

-

-

-

-

18.3

12.2

6.1

0

-6.1

-12.2

-21.4

-

-

-

-

-

2 4.3

8.3

-8.3

-

-

-

-

-

-

-

-

-

Operating display
without changes

Operating display

Set value
to table value
+ display value

7800-8
7800-12
7800-19
7800-48