6

2. Technical data

2.1 Mechanical data

*

1

Irrespective of counter pressure

*

2

Maximum suction lift 1 metre

2.2 Electrical data

2.3 Input/output data

The pump offers various input and output possibili-
ties, depending on control variant.

7800-

2

7800-

8

7800-

12

7800-

19

7800-

48

Maximum capacity without anti-cavitation *

1

[l/h]

2.5

7.5

12

18.5

48

Maximum capacity with anti-cavitation *

1

[l/h] 1.8 5.6 9 14.5 37

Maximum pressure [bar]

18

10

6

6.2

2.6

Maximum stroke rate per minute [stroke/min.]

180

180

180

151

151

Maximum suction lift during operation [m]

6

Maximum suction lift when priming with wet valves [m]

1.8

3

3

3

3

Maximum viscosity with spring-loaded valves *

2

[mPas]

500

500

500

500

100

Maximum viscosity without spring-loaded valves *

2

[mPas]

200

200

200

200

100

Diaphragm diameter [mm]

28

38

42.5

55

77

Liquid temperature [°C]

0 to 50

Ambient temperature [°C]

0 to 45

Accuracy of repeatability

±1%

Sound pressure level [dB(A)]

<70

7800-

2, 8, 12

7800-

19, 48

Supply voltage [VAC]

1 x 100-240

Maximum current consumption [A]

at 100 V

0.30

0.36

at 230 V

0.16

0.26

Maximum power consumption P

1

[W]

18

22

Frequency [Hz]

50-60

Enclosure class

IP 65

Insulation class

B

Supply cable

1.5 m H05RN-F with plug

Signal input

Voltage in level sensor input [VDC]

5

Voltage in pulse input [VDC]

5

Minimum pulse-repetition period [ms]

3.3

Impedance in analog 4-20 mA input [

]

250

Maximum loop resistance in pulse signal circuit [

]

350

Maximum loop resistance in level signal circuit [

]

350

Signal output

Maximum load of alarm relay output, at ohmic load [A]

2

Maximum voltage, alarm relay output [V]

250