Burkert Type S030 User Manual

Page 3

Advertising
background image

8

note

the fitting may be damaged by the fluid in contact
with.
• Systematically check the chemical compatibility of the

component materials of the fitting and the fluids likely

to come into contact with it (for example: alcohols,

strong or concentrated acids, aldehydes, alkaline

compounds, esters, aliphatic compounds, ketones,

halogenated aromatics or hydrocarbons, oxidants and

chlorinated agents).

English

9

4. GenerAl informATion

To contact the manufacturer of the fitting use following
address:
Bürkert SAS
Rue du Giessen
BP 21
F-67220 TRIEMBACH-AU-VAL

The addresses of our international branches can be found
on the Internet at:

www.burkert.com

Warranty conditions

The condition governing the legal warranty is the conforming
use of the S030 in observance of the operating conditions
specified in this manual.

information on the internet

You can find the user manuals and technical data sheets
regarding the type S030 at:

www.burkert.com

English

9

10

5. deScripTion
Area of application

The S030 HT fitting is intended to measure the flow rate of

clean fluids in DN6 to DN50 pipes thanks to its paddle-wheel.

Its combination with an SE30 HT electronic module builds a
flowmeter 8030 HT.
The electronic device can be removed without opening the
piping or stopping the process.

measuring principle

The fluid flowing in the piping makes the paddle-wheel turn.
The paddle-wheel rotational frequency f is proportional to
the flow rate.

English

11

6. TecHnicAl dATA
conditions of use

Ambient temperature
(operating)

-15 to +80 °C, if the fitting is com-
bined with an SE30 HT electronic
module

Pressure class

• PN40 if -15 °C < T fluid < 90 °C
• PN25 if

90 °C < T fluid

125 °C

Fluid temperature

-15 to +125 °C

conformity to the pressure
directive

The S030HT fitting complies with article 3 of §3 from
97/23/CE directive.
Acc. to the 97/23/CE pressure directive, the fitting can
only be used in the following cases (depending on max.
pressure, pipe diameter and fluid):

type of fluid

conditions

Fluid group 1 § 1.3.a only DN ≤ 25
Fluid group 2 § 1.3.a DN ≤ 32

or DN > 32 and PNxDN ≤ 1000

Fluid group 1 § 1.3.b PNxDN ≤ 2000

English

11

Advertising