Burkert Type S030 User Manual

Page 7

Advertising
background image

24

50 x DN 5 x DN

40 x DN 5 x DN

25 x DN 5 x DN

20 x DN 5 x DN

18 x DN 5 x DN

15 x DN 5 x DN

With control valve

Pipe with 2 elbows

at 90°

Pipe with 2 elbows at 90°

in 3 dimensions

Pipe with 1 elbow at 90°

or 1 T-piece

With pipe expansion

With pipe

reduction

Fig. 2: Upstream and downstream distances depending

on the design of the pipes.

Use a flow conditioner, if necessary, to obtain the best
accuracy.

English

25

Prevent the formation of air bubbles in the pipe (see
Fig. 3).

Ensure the pipe is always filled with liquid (see Fig. 4).

Correct

Correct

Incorrect

Incorrect

Direction of fluid flow

Fig. 3: Additional recommendations on installation

English

25

26

Correct

Incorrect

Correct

Incorrect

Fig. 4: Additional recommendations on installation

installing a fitting with weld ends

Follow the previously described general installation
recommendations.

English

27

note

the seal on the fitting with weld-end connections
may be damaged during welding.

Before welding the weld-ends, unscrew the 4 tight-
ening screws.

Remove the sensor holder.

Remove the seal.

Weld the weld-ends.

After welding, correctly replace the seal in the
groove.

Replace the sensor holder.

Tighten the 4 screws in an alternating pattern, app-
lying a nominal tightening torque of 1,5 Nm.

English

27

Advertising