InstallationandWiring

Type 8071

7.

insTAllATion AnD WirinG

7.1.

safety instructions

danger

risk of injury due to high pressure in the installation.
• Stop the circulation of fluid, cut off the pressure and drain the

pipe before loosening the process connections.

risk of injury due to electrical voltage.
• Shut down and isolate the electrical power source before

carrying out work on the system.

• Observe all applicable accident protection and safety regula-

tions for electrical equipment.

risk of injury due to the nature of the fluid.
• Respect the prevailing regulations on accident prevention and

safety relating to the use of aggressive fluids.

risk of injury due to high fluid temperatures.
• Use safety gloves to handle the device.
• Stop the circulation of fluid and drain the pipe before loosening

the process connections.

• Keep all easily flammable material and fluid away from the

device.

6.4.

K factors (in pulse/l)

Flow rate range

K factor (in pulse/l)

0,5- 50 l/h

1552

2- 100 l/h

1000

15- 500 l/h

400

If the device is combined with an instrument which does not
automatically convert the K factors, make the conversion
using one of the following formulae:

K factor in pulse/gallon US = K factor in pulse/l x 3,785 to
obtain flow rate in gallon US / time unit

K factor in pulse/gallon UK = K factor in pulse/l x 4,546 to
obtain flow rate in gallon UK / time unit.