Diverter Valve Wiring Connection: The plug for the diverter valve is at the end of the exterior

wiring harness and will be marked with code BB. The plug and wire will run down the LH side of tractor
from the front mounted hydraulic pump / Tank. The diverter valve is bolted the the LH front Frame
Mount bracket. The holes are already in the bracket and the diverter valve should have already been
mounted. If valve has not been mounted it can be mounted now (See Figure 27, 28 , 31 & 38).

Exterior Wire Harness Schematic P/N 02981375A

Pressure

Supply

Port "P"

Return

To Tank

"T"

"B"

"A"

"A"

"A"

"A"

"A"

"A"

"B"

"B"

"B"

"B"

"B"

Swing

Lift

T

e

lescope

Head T

ilt

Head Swivel / Door

(T

o Diverter V

alve)

Dipper

G

G/W

OR

R/W

Y/W

B/W

OR/

W

Y

R

B

G/W

G

Six Spool Control Valve

FIGURE 28

External Wire Connec-
tions for valve are marked
"A" and "B" on Valve &
AA1 thru AA12 on wire
harness connections

A A

11

A A

12

B

A

A A

9

A A

10

B

A

A A

7

A A

8

B

A

A A

5

A A

6

B

A

A A

3

A A

4

B

A

A A

2

A A

1

B

A

XT2 (Expansion, Transmission)

FIGURE 30

Bolts on RH side

on side of Tank

XP2 (Expansion, Power)

Bolts on LH side

in front of Valve

FIGURE 29

Advertising